Loading...
Here are the answers to the July 28, 2022 edition of TPO's Exam Study Guide: Given the following data: MLSS 1,900 mg/l; RMLSS 3,200 mg/l; Plant Q 1.65 mgdAeration tank volume 2.5 mg; RAS Q .9 mgdClarifier Volume .75 mg; aeration tank DO 3.2 mg/l How much sludge should be wasted to maintain a target MLSS of 1,750 mg/l? The answer to this question is B, 117,000 gallons. This can be solved using the pounds formula. It is a rather simple method of determining waste amounts using a target MLSS. First determine the number of pounds of sludge to be wasted, then by solving for the unknown,
Please login or register to view TPO articles. It's free, fast and easy!